Rtd module, Features, Functional description – Basler Electric BE1-11m User Manual

Page 507: Analog inputs, Rtd inputs, Analog outputs, Alarm contact functions, Real-time status functions

Advertising
background image

9424200996 Rev L

495

RTD Module

The RTD (Resistance Temperature Detector) module is an optional remote device that provides RTD
inputs, analog inputs, and analog outputs for motor protection applications.

Features

RTD modules have the following features:

12 RTD Inputs

4 Analog Inputs

4 Analog Outputs

Secured Read/Write Access

*

Reporting and Alarm Functions

Communications via Ethernet or RS-485

* The default password for uploading settings to the RTD module is “OEM” in upper case letters.

Functional Description

A functional description of the RTD module’s inputs and outputs is provided below.

Analog Inputs

The RTD module provides four analog inputs that are user-selectable for 4 to 20 mAdc or 0 to 10 Vdc.
Each analog input has under/over thresholds that when exceeded, trip an analog input protection
element. The label text of each analog input is customizable.

RTD Inputs

The RTD module provides 12 user-configurable RTD inputs for monitoring motor systems. Each RTD
input can be configured to protect against high or low temperature conditions. The label text of each RTD
input is customizable.

Analog Outputs

The RTD module provides four analog outputs that are user-selectable for 4 to 20 mAdc or 0 to 10 Vdc. A
wide selection of parameters including BE1-11m metered voltages and currents, analog inputs, and RTD
inputs can be configured as analog outputs. Refer to the Programmable Outputs, Remote Analog Outputs
screen in BESTCOMSPlus

® for a full list of parameter selections.

Alarm Contact Functions

The RTD module provides form C (SPDT) alarm contacts that operate when an internal RTD module
failure exists. The contacts also operate when operating power is cycled.

Real-Time Status Functions

The RTD module is equipped with a multi-function LED with the following functions.

Slow Flashing - Communications established

Quick Flashing - Communications lost

Steady On

- Power applied

BE1-11m

RTD Module

Advertising