258

9424200996 Rev L

Figure 211. RS-485 DB-37 to BE1-11m

Ethernet Setup

Located on the rear panel, the optional Ethernet communication port provides dynamic addressing
(DHCP), Web pages (HTTP), email alerts (SMTP), as well as communication with a PC running
BESTCOMSPlus, Modbus

, or DNP software. Additional Ethernet settings are illustrated in Figure 212.

The Enable Web Pages box must be checked to enable viewing of BE1-11m web pages. Refer to the

BESTnet

™Plus

chapter for more information on viewing web pages.

Figure 212. Ethernet Screen

Ethernet Port Configuration

Initially you must use a USB connection on the front panel to configure communications.

1.

Connect an Ethernet cable between the BE1-11m and your network.

2.

Connect a USB cable between the BE1-11m and your PC.

3.

Apply operating power to the BE1-11m and wait until the boot sequence is complete.

4.

Use BESTCOMSPlus to connect to the BE1-11m through the USB port.