Contact Output Logic Override Control

BESTCOMSPlus Navigation Path: Metering Explorer, Control, Output Override

HMI Navigation Path: Metering Explorer, Control, Output Override Contacts

Each contact output can be controlled directly using the select-before-operate output control function. The
output logic expression that normally controls the state of an output can be overridden and the contact
pulsed, held open, or held closed. This function is useful for testing purposes. An alarm point is available
in the programmable alarm function for monitoring when the output logic has been overridden. See the

Alarms

chapter for more information about programmable alarms. Output logic override control is

achieved using the front-panel interface or BESTCOMSPlus. Use the Metering Explorer to open the
Control, Output Override screen. Refer to Figure 31.

Figure 31. Output Override Screen

Enabling Logic Override Control

By default, logic override control is disabled. Output logic override must be enabled before the control can
be used. Enabling of the output logic override control is not possible at the front panel. It can only be
enabled through a communication port using BESTCOMSPlus (Figure 31). Click on the Disabled button
next to the output you want to control. This button will change to Enabled and the following three action
choices will appear to the right: Reset, Set, and Pulse.

Pulsing a Contact Output

Pulsing BE1-11m outputs provides the user the ability to test the operability of an output without
energizing a measuring or timing element. This feature is useful when testing the protection and control
system. When pulsed, an output changes from the current state (as determined by the virtual output logic
expression) to the opposite state for 200 milliseconds. After 200 milliseconds, the output is returned
automatically to logic control.