5. Commissioning

5-6

Festo P.BE-MTR-DCI-CO-EN en 1209a

1. Switch on the power supply for the MTR-DCI. When the

power supply is switched on, the MTR-DCI automatically
carries out an internal check. Preset operating mode after
switching on Record Select

2. Carry out parametrizing and commissioning with the con-

trol panel or the FCT software, as described in the follow-
ing chapters or in the FCT/PlugIn help.

3. In order to complete commissioning note the instructions

for operation in the FCT/PlugIn help and in chapter 5.7.

Note
To restore the default settings, the EEPROM can be deleted
if necessary with CI object 20F1 (Data memory control)
directly via the serial interface (see section C.3). User-spe-
cific settings will then be lost.

Use CI commands only if you already have experience of
Service Data Objects.

If necessary consult Festo.

Warning
Danger of injury.

Faults in parametrizing can cause injury to human beings
and damage to property. In the following cases reference
travel is absolutely essential in order that the reference
coordinates and the working range can be set correctly:

– with the first commissioning

– when the homing method is changed

each time the logic voltage supply is switched on