Reference travel (requires status 1.4 or 1.5), Commissioning 5-54 – Festo Электромотор MTR-DCI User Manual

Page 152

Advertising
background image

5. Commissioning

5-54

Festo P.BE-MTR-DCI-CO-EN en 1209a

4. Reference travel (requires status 1.4 or 1.5)

4.1

A positive edge at CPOS.B2 (HOM, Start homing) starts
reference travel. The start is confirmed with SPOS.B1
(Acknowledge Start) as long as CPOS.B2 (HOM) is set.

4.2

Movement of the axis is shown with SPOS.B4 (MOV,
Axis moves).

4.3

After successful reference travel SPOS.B2 (MC, Motion
Complete) and SPOS.B7 (REF) will be set.

Step/
Description

Output data

Input data

Byte

B7 B6

B5 B4

B3

B2 B1 B0

Byte

B7 B6 B5 B4 B3 B2 B1 B0

4.1 Start reference
travel

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP ENABL

E

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

E

CCON

0

x

x

0

0

x

1

1

SCON

0

x

0

1

0

0

1

1

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HOLD

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HOLD

CPOS

0

0

0

0

0

F

0

1

SPOS

0

0

0

0

0

0

1

1

4.2 Reference travel
runs

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP ENABL

E

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

E

CCON

0

x

x

0

0

x

1

1

SCON

0

x

0

1

0

0

1

1

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HOLD

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HOLD

CPOS

0

0

0

0

0

1

0

1

SPOS

0

0

0

1

0

0

1

1

4.3 Reference travel
concluded

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP ENABL

E

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

E

CCON

0

x

x

0

0

x

1

1

SCON

0

x

0

1

0

0

1

1

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HOLD

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HOLD

CPOS

0

0

0

0

0

0

0

1

SPOS

1

0

0

0

0

1

0

1

0: 0-signal

1: 1-signal;

x: not relevant (optional);

F: Edge positive

Tab. 5/11: I/O data “Reference travel”

If there are faults during reference travel:
} Error treatment: see example 3, Tab. 5/10.