Festo Электромотор MTR-DCI User Manual

Page 241

Advertising
background image

B. Reference – Festo Handling and Positioning Profile (FHPP)

B-23

Festo P.BE-MTR-DCI-CO-EN en 1209a

Data Memory Control

FHPP

127

1, 2

Array

uint8

rw

1)

Description

Commands for the EEPROM (non-volatile data storage)

Delete EEPROM 127

1

uint8

rw

When the object has been written and after Power Off/On the data in the
EEPROM are reset to the factory settings.
Fixed: 16 (0x10): Delete data in EEPROM and restore factory settings).
Observe the note below.

Save data 127

2

uint8

rw

The data in EEPROM will be overwritten with the current user-specific settings.
Fixed 1 (0x01): Save data

CANopen / CI

20F1h

01h, 02h

Array

uint8

rw

1)

1)

When reading the reply “0” always occurs

Note
All user-specific settings will be lost when the EEPROM is
deleted (except for cycle number). The status after dele-
tion corresponds to the standard factory setting.

Always carry out a first commissioning after deleting the
EEPROM.

When the EEPROM is deleted, the field bus parameters
are also reset.