5. Commissioning

5-18

Festo P.BE-MTR-DCI-CO-EN en 1209a

5.2.5

Teach position records

Enter the position records as follows:

1. Activate the desired position record (1...31) with

[Settings] [Position set] [Position nr].

2. Select the positioning mode of the position set.

Select [Pos set mode].

Set the positioning mode with the arrow keys:
absolute = absolute position specification, related to

the project zero point

relative = relative position specification, related to

the current position.

Accept the value with OK <Enter>.

3. Teach the target position of the position record:

Select [Position].

Move the drive manually to the desired target position
with the arrow keys.

Accept the position reached with OK <Enter>. The
setting of the target position and the positioning
mode will then take effect in the drive.

4. Set the speed:

Select [Velocity].

Set the nominal speed with the arrow keys.

Accept the setting with OK <Enter>. The setting will
then take effect in the drive.

Position records with speed v = 0 or invalid target positions
(-> error TARGET POSITION OUT OF LIMIT) cannot be
executed.

} Settings

Position set

Position no.
Pos set mode
Position
Velocity
SAVE