Festo Электромотор MTR-DCI User Manual

Page 193

Advertising
background image

6. Diagnostics and error display

6-9

Festo P.BE-MTR-DCI-CO-EN en 1209a

Warning

Warnings have no influence on the reaction of the drive. The
cause of the warning should be eleiminated in order that it
does not lead to a fault.
If a warning occurs, the fault LED will flash and the WARNING
output will be set (FHPP status bits, SCON.B2).

Warning

Cause

HOT
TEMPERATURE

Operating temperature 70 °C < T < 80 °C,
Check whether drive is overloaded, check the
mechanical parts, e. g. for stiffness, reduce
ambient temperature.

COLD
TEMPERATURE

Operating temperature < –10 °C,
Increase the ambient temperature as
appropriate.

STANDSTILL
WARNING

The axis has moved outside the standstill
tolerance window.

ILLEGAL
RECORD
WARNING

Non-permitted record number

Fault

If there is a fault, the drive will be stopped. The fault LED will
flash.

1. Eliminate the cause of the fault.

2. Quit the fault message:

With <Enter> on the control panel,

via the field bus with a falling edge at the ENABLE
signal,

via the field bus with a rising edge at the RESET signal
CCON.B3,

with the button “Quit error” in the Festo Configuration
Tool.

Advertising