Warning
Warnings have no influence on the reaction of the drive. The
cause of the warning should be eleiminated in order that it
does not lead to a fault.
If a warning occurs, the fault LED will flash and the WARNING
output will be set (FHPP status bits, SCON.B2).
Warning
Cause
HOT
TEMPERATURE
Operating temperature 70 °C < T < 80 °C,
Check whether drive is overloaded, check the
mechanical parts, e. g. for stiffness, reduce
ambient temperature.
COLD
TEMPERATURE
Operating temperature < –10 °C,
Increase the ambient temperature as
appropriate.
STANDSTILL
WARNING
The axis has moved outside the standstill
tolerance window.
ILLEGAL
RECORD
WARNING
Non-permitted record number
Fault
If there is a fault, the drive will be stopped. The fault LED will
flash.
1. Eliminate the cause of the fault.
2. Quit the fault message:
–
With <Enter> on the control panel,
–
via the field bus with a falling edge at the ENABLE
signal,
–
via the field bus with a rising edge at the RESET signal
CCON.B3,
–
with the button “Quit error” in the Festo Configuration
Tool.