5 input for external reference switch – Festo Электромотор MTR-DCI User Manual
Page 65
3. Installation
3-13
Festo P.BE-MTR-DCI-CO-EN en 1209a
3.5
Input for external reference switch
If you are not using a reference switch:
•
Seal the terminal with the protective cap supplied
(ISK-M8).
Selecting the reference switch:
•
Use the correct switch type “normally-open contact” in
the PNP variant for the reference switch.
•
Usea reference switch with screw locking (outer thread
M8x1) at the end of the cable or, as adapter, the connect-
ing cable KM8-M8-... with screw locking.
Use e. g. the following proximity switches from Festo:
–
Magnetic proximity switches SMT-8M-...
–
Inductive proximity sensor SIEN-...-M8B-...
•
When selecting the sensor, note that the accuracy of the
switchover point of the sensor determines the accuracy of
the reference point.
M8x1 socket
Description
1
3
4
1
DC +24 V
DC +24 V voltage output
(only for reference switch)
4
REF
Contact reference switch
3
GND
Ground
Tab. 3/7: Connection REF (reference switch) on the MTR-DCI
The power supply for the reference switch (DC 24 V/Ground)
is provided via pin 1/3.