background image

4. Control panel (only type MTR-DCI-...-H2)

4-19

Festo P.BE-MTR-DCI-CO-EN en 1209a

4.5.3

[Settings] [Homing paramet.]

Setting the reference travel method and the speed during
reference travel. Observe the instructions in chapter 5.2.2.

The maximum speed during reference travel is limited to half
the maximum positioning speed v_max (v_max see [Diagnos-
tics] [Axis parameter] ).

[Hom. paramet.]

Param.

Description

[Homing method]

sw.neg
(switch negative)

Homing to reference switch, negative = factory setting

sw.pos
(switch positive)

Homing to reference switch, positive

bl.neg
(block negative)

Homing to fixed stop, negative

bl.pos
(block positive)

Referencing to
fixed stop, positive

[Velocity v_sw]

v_sw

Speed for searching for the reference point

[Velocity v_s0]

v_s0

Speed for moving to the axis zero point

[SAVE...]

Save parameters in EEPROM

Tab. 4/8: Menu [Settings] [Homing paramet.]

Choose [SAVE...] to save the parameter settings.