Festo Электромотор MTR-DCI User Manual

Page 266

Advertising
background image

B. Reference – Festo Handling and Positioning Profile (FHPP)

B-48

Festo P.BE-MTR-DCI-CO-EN en 1209a

Position Control Parameter Set

FHPP

1024

18...23, 32

Array

uint16

rw

Description

Technical control parameters.
Modification is only permitted for servicing purposes.
If necessary consult Festo.

Gain position 1024

18 (CI: 12h)

rw

Gain position controller
Value range:
MTR-DCI-32:1...100;

MTR-DCI-42/52/62: 1...200

Default:
MTR-DCI-32:20;

MTR-DCI-42:15;

MTR-DCI-52:10;

MTR-DCI-62:8

Gain speed 1024

19 (CI: 13h)

rw

Gain speed controller
Value range: MTR-DCI-32: 1...3000; MTR-DCI-42/52/62: 1...700
Default: MTR-DCI-32: 2800; MTR-DCI-42/52: 600; MTR-DCI-62: 500

I-fraction speed

1024

20 (CI: 14h)

rw

I-share speed controller
Value range: 1...600
Default: MTR-DCI-32: 80; MTR-DCI-42/52/62: 340

Gain current 1024

21 (CI: 15h)

rw

Gain current controller
Value range: MTR-DCI-32: 1...1000; MTR-DCI-42/52/62: 1...800
Default: MTR-DCI-32: 110; MTR-DCI-42/52/62: 150

I-fraction

1024

22 (CI:16h)

rw

I-share current controller
Value range: MTR-DCI-32/42/52: 0...1000
Default: MTR-DCI-32: 90; MTR-DCI-42: 420; MTR-DCI-52: 350

Gain velocity 1024

23 (CI: 17h)

rw

Gain speed controller - trajectory generator
Value range: 1...2. Default: 1

Save position 1024

32 (CI: 20h)

rw

Saves the current position in EEPROM when the device is switched off.
Fixed = 240 (0x00F0): Current position will not be saved after Power-off.

CANopen / CI

60FBh

12h...17h, 20h

Array

uint16

rw

Advertising