4 [settings] [position set – Festo Электромотор MTR-DCI User Manual

Page 92

Advertising
background image

4. Control panel (only type MTR-DCI-...-H2)

4-20

Festo P.BE-MTR-DCI-CO-EN en 1209a

4.5.4

[Settings] [Position set]

Programming the position record table

Select the number of the desired position set. The follow-
ing settings refer to the currently selected position set.
Note also the instructions on programming the position
sets in chapter 5.2.5.

[Position set]

Param.

Description

[Position no.]

No.

Number of the position set

[Pos set mode]

[absolute/
relative]

Positioning mode
absolute = absolute position specification, related to the
project zero point
relative = relative position specification, related to the current
position

[Position]

xt

Teach mode for setting the target position in the selected
measuring system e.g. [mm].
Do not teach the positions until the reference system has been
defined by means of a reference run. (see chapter 4.4.3)

[Velocity]

v

Positioning speed in the selected measuring system e.g. [mm/s]

[SAVE...]

Save parameters in EEPROM

Tab. 4/9: Menü [Settings] [Position set]

<- ->

You can move the axis into the desired position or
select the parameter setting with the arrow buttons.

OK

You can accept the selection with the <Enter> button.

ESC

With the <Menu> button you can interrupt the activ-
ity and return to the higher-order menu.

Choose [SAVE...] to save the parameter settings. Only then
will the settings be retained even when the power supply
is switched off or if there is a power failure.

Advertising