A.2 accessories – Festo Электромотор MTR-DCI User Manual

Page 206

Advertising
background image

A. Technical appendix

A-6

Festo P.BE-MTR-DCI-CO-EN en 1209a

CANopen data

Design
– Physical Layer
– Data Link Layer

as per ISO 11898 (corresponding to DS 102)
as per CAN specification 2.0

CAN protocol

as per DS 301 and CiA 402

Manufacturer ID

29 (0x1D)

Profile ID (device type)

Dependent on data profile:
– CiA 402:

131474

(0x00420192)

– FHPP:

301

(0x0000012d)

Address range (node ID).

1 ... 127

Transmission rate

20, 50, 100, 125, 250, 500, 800 and 1000 kBit/s

Interface
– Plug
– Electrical isolation depending on parameteriz-

ation (see sections 3.3.2, 4.5 and 5.2.7)

– Integrated bus termination

D-Sub, 9-pin
Parameter “CAN Voltage Supply”:
– internal: No electrical isolation (default)
– external: Electrical isolation
No

Cable type

Dependent on cable length and fieldbus bit rate,
see controller manual or DS 102.

A.2

Accessories

Connection

Accessories

Designation

Length [m]

Voltage supply

Power supply cable

KPWR-MC-1-SUB-9HC-...

2.5 / 5 / 10

Serial interface

Programming cable

KDI-MC-M8-SUB-9-...

2.5

Reference switch

Switch, magnetic
Switch, inductive

SMT-8M-...-M8D
SIEN-...-M8B-...

Connecting cable with
screw-type lock

KM8-M8-GSGD....

0.5 / 1 / 2 / 5

Field bus connection
incl. logic power
supply

Field bus adapter (IP54)

FBA-CO-SUB-9-M12