Festo Электромотор MTR-DCI User Manual
Page 298

C. Reference – CANopen and CI objects
C-22
Festo P.BE-MTR-DCI-CO-EN en 1209a
Diagnostic memory parameter
CANopen / CI
20CCh
01h...04h
Array
uint8
rw/ro
Description
Configuration of the diagnostic memory, see PNU 204, section B.2.6.
Fault type 20CCh
01h
uint8
rw
Incoming and outgoing faults
Resolution 20CCh
02h
uint8
rw
Resolution time stamp
Clear Memory 20CCh
03h
uint8
rw
Clear diagnostic memory by writing value = 1.
Number of entries 20CCh
04h
uint8
ro
Read out the number of entries in the diagnostic memory.
FHPP
204
1...4
Array
uint8
rw/ro
Scaling
CANopen / CI
20D0h
01h, 02h
Array
uint8
rw/ro
Description
Settings on the control panel HMI (only type MTR-DCI-...H2)
Influences only the display: All parameters are saved internally in increments.
Measuring unit 20D0h
01h
uint8
rw
Determining the measuring unit system for the control panel
1 (0x01): Metric measuring units (mm, mm/s, mm/s
2
)
4 (0x04): Angle degree
8 (0x08): Revolutions
Compare PNU126/20FFh.
Scaling factor 20D0h
02h
uint8
ro
Number of post-decimal positions Fixed = 2. Compare PNU126/20FFh.