C.1.3 manufacturer specific profile area – Festo Электромотор MTR-DCI User Manual

Page 295

Advertising
background image

C. Reference – CANopen and CI objects

C-19

Festo P.BE-MTR-DCI-CO-EN en 1209a

C.1.3

Manufacturer specific profile area

Record number

CANopen / CI

2032h

01h

Array

1)

uint8

rw

1)

Pseudo-array due to compatibility

Description

Select a position record via the record number.
The record number is saved as the target for write and read operations on the
following Objects:
– Object 20E0/01h...05h: position_table_element
– or objects 607Ah, 6081h, 6083h, 6084h.
There is a direct correlation with object 2033h (PNU 401).

Record number 2032h

01h

uint8

rw

Read or write record number
Values:
0 (0x00): CANopen direct position record
1 (0x00): CANopen RS232 position record
2 (0x02): Homing (position record 0)
3 (0x03): Position record 1 (default)
4 (0x04): Position record 2
...

Position record ...

33 (0x21): Position record 31

Record
number

MTR-DCI

2032h

Record
number
uint8

20E0/01h

RCB1
uint16

20E0/02h

Nominal
(target)
position
int32

20E0/03h

Velocity
int32

20E0/04h

Acc. Movement
to
int32

0

2

Homing

1

3

...

...

...

...

2

4

...

...

...

...

...

...

...

...

...

...

31

33

...

...

...

...

Tab. C/2: Structure of CiA 402 record list

For CiA 402, the record is selected with object 2032h. The
selected record is then addressed with object 20E0h,
whereby the record element (column in Tab. C/2) with the
sub-index is selected. From the value received via object
2032h, subtract 2 in order to get the internal record number.

Advertising