5. Commissioning

5-76

Festo P.BE-MTR-DCI-CO-EN en 1209a

Overview of parameters involved (see section B.2.9)

Parameters involved

Description

FCT

PNU

CO/CI

Nominal values for
positioning mode

Max. permitted speed

1)

x

502

21F6/00h

Direct mode acceleration in acceleration unit
(inc/s

2

)

x

541

20EE/22h

Start
(FHPP control byte)

CPOS.B1 = positive edge: Start
(CDIR.B0 = nominal position absolute/relative)

Reply message
(FHPP status byte)

SPOS.B2 = 0: Motion Complete
SPOS.B1 = positive edge: Quit Start
SPOS.B4 = 1: Drive moves

Requirement

Device control by PLC/field bus
Controller must be in status “Operation enabled”

1)

In the output data the master transfers a percent value which is multiplied by the maximum
permitted speed, in order to achieve the final nominal speed.

Tab. 5/21: Parameters involved in Direct mode (positioning mode)

Power operation

Power operation is used in the following situations:

For clamping and holding work items as well as for pro-
cedures in which work items must be orientated (e. g. on
a fixed stop).

Pressing and inserting procedures.

Special functions in which e. g. work items must be
touched in order to receive position values.