5. Commissioning

5-56

Festo P.BE-MTR-DCI-CO-EN en 1209a

Step/
Description

Output data

Input data

Byte

B7 B6

B5 B4

B3

B2 B1 B0

Byte

B7 B6 B5 B4 B3 B2 B1 B0

5.1 Preselect record
number (byte 3)

Byte3

Record number

Byte 3

Record number

Re-
cord
no.

Record no. (0...31)

Re-
cord
no.

Previous record no. (0...31)

5.2 Start order

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP ENABL

E

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

E

CCON

0

0

x

0

0

x

1

1

SCON

0

0

0

1

0

0

1

1

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HOLD

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HOLD

CPOS

0

0

0

0

0

0

F

1

SPOS

1

0

0

0

0

0

1

1

5.3 Order runs

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP ENABL

E

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

E

CCON

0

0

x

0

0

x

1

1

SCON

0

0

0

1

0

0

1

1

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HOLD

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HOLD

CPOS

0

0

0

0

0

0

1

1

SPOS

1

0

0

1

0

0

1

1

Byte3

Record number

Byte 3

Record number

Re-
cord
no.

Record no. (0...31)

Re-
cord
no.

Current record no. (0..0.31)

5.4 Order concluded

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP ENABL

E

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

E

CCON

0

0

x

0

0

x

1

1

SCON

0

0

0

1

0

0

1

1

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HOLD

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HOLD

CPOS

0

0

0

0

0

0

0

1

SPOS

1

0

0

0

0

1

0

1

Byte 5...8

reserved

Byte 5...8

Position

reserved

Actual
posi-
tion

Actual position (increments)

0: 0-signal

1: 1-signal;

x: not relevant (optional);

F: Edge positive

Tab. 5/12: I/O data “Record Select: positioning mode”