Festo Электромотор MTR-DCI User Manual

Page 309

Advertising
background image

C. Reference – CANopen and CI objects

C-33

Festo P.BE-MTR-DCI-CO-EN en 1209a

Target position

CANopen / CI

607Ah

– / 00h

Var

int32

rw

Description

Target position in increments. Compare 20E0/02h.
Writing the object does not yet trigger movement.
CiA 402: Current target that the drive should approach in positioning mode,
interpreted as relative or absolute dependent on bit 6 in control word 6040h.
FHPP: The target position will be stored in the intended line addressed by ob-
ject 2032h in the column intended in the position table for the direct mode.
Value range: -2

31

... +(2

31

-1)

Position range limits (software end positions)

CANopen / CI

607Bh

01h, 02h

Array

int32

rw

Description

Software end positions in increments, see PNU 501, section B.2.9.

Lower limit 607Bh

01h

int32

Lower software end position

Upper limit 607Bh

02h

int32

Upper software end position

FHPP

501

1, 2

Array

int32

rw

FHPP: “Software end positions”

Home offset (offset axis zero point)

CANopen / CI

607Ch

– / 00h

Var

int32

rw

Description

Axis zero point offset in increments, see PNU 1010, section B.2.16.

FHPP

1010

Var

int32

rw

FHPP: “Offset axis zero point”

Polarity (reversal of direction)

CANopen / CI

607Eh

– / 00h

Var

uint8

rw

Description

The direction of the position values is reversed.
see PNU 1000, section B.2.15.

FHPP

1000

Var

uint8

rw

Advertising