A.1 technical specifications – Festo Электромотор MTR-DCI User Manual

Page 203

Advertising
background image

A. Technical appendix

A-3

Festo P.BE-MTR-DCI-CO-EN en 1209a

A.1

Technical specifications

General information

Protection class as per EN 60529

IP54 (plug connector inserted or fitted with protec-
tive cap)

Relative humidity

0 to 95 %, non-condensing

Temperature range

operation: 0 ... +50 °C
storage/transport: -25 ... +60 °C

Vibration

As per DIN/IEC 68/EN 60068 part 2-6,
Severity level 1

Shock

As per DIN/IEC 68/EN 60068 part 2-27,
Severity level 1

Protection against electric shock

1)

Protection against direct and indirect contact as per
IEC/DIN EN 60204-1 by PELV circuits (Pro-
tected Extra-Low Voltage)

Electromagnetic compatibility (EMC)

2)

see conformity declaration (www.festo.com)

Gear type

Planetary gear

Encoder (with 4-fold evaluation)

MTR-DCI-32: 300 x 4 —> 1200 Inc/revolution
MTR-DCI-42,52,62: 500 x 4 —> 2000 Inc/revolution

Temperature monitoring

Warning message at 70 °C < T < 80 °C
Shut-down at temperature ≥ 80 °C

Display resolution

128 x 64 pixels

1)

The device is intended for industrial use.

2)

The maximum permitted I/O signal cable length is 30 m.