2. Mounting

2-7

Festo P.BE-MTR-DCI-CO-EN en 1209a

Note
Motor unit MTR-DCI-62-...-G22 can generate up to 37 Nm
at a peak current of 20 A in the start-up phase.

Make sure by calculating the dynamic loading that
the maximum permitted shaft output torque of the gear
is not exceeded in the start-up phase (e.g. by reducing
the load).

Use the thread on the front of the gear (see Fig. 2/2) for fit-
ting the MTR-DCI to a mechanical drive device (machine
frame).

In order to minimize the shaft offset: Position the axis with
the aid of the centring diameter (D1 or D3 see Tab. 2/1)
relative to the rotary axis of the mechanism to be driven.

Fasten the motor unit with 4 screws and tighten the
4 screws with the specified tightening torque.

The motor unit MTR-DCI-32 has a total of 6 threads for differ-
ent motor mounting variants (axial, parallel). In each case
only 4 screws must be used.

Size

Thread depth

Tightening torque

MTR-DCI-32-...

M3

6 mm

1.2 Nm

MTR-DCI-42-...

M3

7 mm

1.2 Nm

M4

10 mm

2.9 Nm

MTR-DCI-52-...

M5

10 mm

5.9 Nm

MTR-DCI-62-...

M5

10 mm

5.9 Nm

Tab. 2/3: Tightening torques