A. Technical appendix

A-15

Festo P.BE-MTR-DCI-CO-EN en 1209a

Parameters

MTR-DCI-32

MTR-DCI-42

MTR-DCI-52

MTR-DCI-62

feed

1)

DMES-18-...:
1500 [μm/red]

DMES-25-...:
2500 [μm/red]

DMES-40-...:
4000 [μm/red]

DMES-63-...:
6000 [μm/red]

enc

2)

300 x 4 =
1200 [incr/rev]

500 x 4 = 2000 [incr/rev]

gear

3)

MTR-DCI-...-G7 (6.75:1)

> 27:4

MTR-DCI-...-G14 (13.73:1)

> 3969:289

MTR-DCI-...-G22 (22.2:1)

> 1710:77

1)

Feed constant: dependent on the axis type, here DMES-...

2)

Encoder resolution for MTR-DCI: impulse four-fold multiplication through digital interpolation

3)

Gear reduction: specification in 2 real numbers for numerator or denominator of the fraction

Tab. A/1: Basis parameter for the measuring system

Drive

Conversion factors UF

Increments

< > millimetres

Increments = millimetres*UF
Millimetres = increments/UF

Increments

< > inch

Increments = inches*UF
Inches = increments/UF

MTR-DCI-32...
(+DMES-18)

-G7
-G14

5400
10986.851211

13716
27906.602076

MTR-DCI-42...
(+DMES-25)

-G7
-G14

5400
10986.851211

137160
27906.602076

MTR-DCI-52...
(+DMES-40)

-G7
-G14

3375
6866.782007

85725
17441.626298

MTR-DCI-62...
(+DMES-63)

-G7
-G14
-G22

2250
4577.854671
7402.597403

57150
11627.750865
18802.597403

Tab. A/2: Special conversion factors for the MTR-DCI with DMES-...