Festo Электромотор MTR-DCI User Manual

Page 240

Advertising
background image

B. Reference – Festo Handling and Positioning Profile (FHPP)

B-22

Festo P.BE-MTR-DCI-CO-EN en 1209a

Device Control

FHPP

125

Var

uint8

rw

Description

Activates device control of the controller via the controller interface.
Corresponds to “HMI control” on the control panel and “FCT/HMI” on the FCT.
0 (0x00): Control via controller interface OFF.

via HMI (control panel) and FCT ON

1 (0x01): Control via controller interface ON (default)

CANopen / CI

207Dh

– / 00h

Var

uint8

rw

HMI Control (MMI parameter)

FHPP

126

1...4

Var

uint8

ro

Description

Settings on the control panel HMI (only type MTR-DCI-...H2)
Influences only the display: All parameters are saved internally in increments.

LCD current 126

1

0

ro

Value range: 1...5 (0x01 ... 0x05). Default: 5

LCD contrast 126

2

1

ro

Value range: 0...63 (0x00 ... 0x3F). Default: 0

Measuring unit 126

3

2

CI rw

Measuring unit system for the control panel. Compare Object 20D0h.
1 (0x01): Metric measuring units (mm, mm/s, mm/s

2

)

4 (0x04): Angle degree
8 (0x08): Revolutions

Scaling factor 126

4

3

CI rw

Number of post-decimal positions Fixed = 2. Compare Object 20D0h

CANopen / CI

20FFh

01h...04h

Array

uint8

rw