5. Commissioning

5-39

Festo P.BE-MTR-DCI-CO-EN en 1209a

5.5.2

Composition of the cyclic I/O data (FHPP standard)

The FHPP standard protocol always contains 8 bytes in-
put and 8 bytes output data.

Further 8 bytes I/O as per FHPP-FPC
In the cyclic data a further 8 bytes input data and 8 bytes
output data are permitted for transmitting parameters in ac-
cordance with the FPC protocol (Festo Parameter Channel).
The I/O data and the parameters are described in section B.1.

Data

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Output
data

Bytes 1 and 2 (fixed)
are retained in each
operating mode and
transmit control and
status bytes (e. g.
CCon, SCON....) for
enabling the MTR-DCI
and for setting the
operating modes.

Bytes 3 to 8 depend on the operating mode selected (Direct mode,
Record select) and transmit further control and status bytes (e. g.
CDir, SDir...), as well as nominal and actual values.
– Record number or nominal position in the output data,
– Return message of actual position and record number in the

input data,

– Further nominal and actual values depending on the operating

mode.

Input
data

I/O data Record select

Data

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Output
data

CCON

CPOS

Record
number

reserved

reserved

Input
data

SCON

SPOS

Record
number

RSB

Actual position

I/O data Direct mode

Data

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Output
data

CCON

CPOS

CDIR

Nominal
value 1
(velocity)

Nominal value 2
(position, force/torque,...)

Input
data

SCON

SPOS

SDIR

Actual
value 1
(velocity,
force/
torque,...)

Actual value 2
(actual position)