Festo Электромотор MTR-DCI User Manual

Page 271

Advertising
background image

B. Reference – Festo Handling and Positioning Profile (FHPP)

B-53

Festo P.BE-MTR-DCI-CO-EN en 1209a

B.2.19 Axis parameters electric drives 1 – Standstill monitoring

Position Target Value (nominal position)

FHPP

1040

Var

int32

ro

Description

Target position of the last positioning task in increments.
Value range: -2

31

... +(2

31

-1)

CANopen / CI

6062h

– / 00h

Var

int32

ro

Position Actual Value

FHPP

1041

Var

int32

ro

Description

Current position of the drive in increments.
Value range: -2

31

... +(2

31

-1)

CANopen / CI

6064h

– / 00h

Var

int32

ro

Standstill Position Window

FHPP

1042

Var

uint32

rw

Description

Standstill position window in increments. Amount by which the drive may move
after MC, until the standstill monitoring responds. Value range: 0...+(2

32

-1).

Default: 750 (0x02EE)

CANopen / CI

2040h

– / 00h

Var

uint32

rw

Standstill Timeout

FHPP

1043

Var

uint16

rw

Description

Standstill monitoring time in [ms}: Time during which the drive must be outside
the standstill position window before the standstill monitoring responds.
Value range: 0...65535 (0xFFFF). Default: 200 (0x00C8)

CANopen / CI

2041h

– / 00h

Var

uint16

rw

Advertising