7 examples of the i/o data, Safeguard device control, Commissioning 5-49 – Festo Электромотор MTR-DCI User Manual

Page 147: Step/ description output data input data

Advertising
background image

5. Commissioning

5-49

Festo P.BE-MTR-DCI-CO-EN en 1209a

5.5.7

Examples of the I/O data

On the following pages you will find typical examples of the
I/O data as per FHPP Standard.

1. Record select: Create readiness to operate

2. Direct mode Create readiness to operate

3. Error treatment

4. Homing

5. Record select: Positioning mode

6. Direct mode Positioning mode

7. Direct mode Power operation

A description of the status machine of the MTR-DCI can be
found in section B.3.

Safeguard device control

Step/
Description

Output data

Input data

Byte

B7 B6

B5 B4

B3 B2 B1

B0

Byte

B7 B6 B5 B4 B3 B2 B1 B0

0.1 device control
HMI = on

Byte 1

OPM2 OPM1

LOCK

RESET BRAKE STOP

ENABL

E

Byte 1

OPM2 OPM1 LOCK

24VL

FAULT WARN OPEN ENABL

E

CCON

0

0

0

0

0

x

0

0

SCON

0

0

1

1

0

0

0

0

Byte 2

CLEAR TEACH JOGN

JOGP

HOM

START

HOLD

Byte 2

REF

STILL

DEV

MOV TEACH

MC

ACK

HOLD

CPOS

0

0

0

0

0

0

0

0

SPOS

0

0

0

0

0

1

0

0

0: 0-signal

1: 1-signal;

x: not relevant (optional);

F: Edge positive

Tab. 5/7: I/O data “Device control active”

Device control via the control panel or the Festo Configuration
Tool is activated. To control the MTR-DCI via the CANopen in-
terface, device control must first be deactivated by FCT/MMI.