background image

C. Reference – CANopen and CI objects

C-15

Festo P.BE-MTR-DCI-CO-EN en 1209a

Receive PDO communication parameter

CANopen

1400h,
1401h

01h...05h

Record

uint32, uint8, uint16

rw

Description

Communication parameters of PDOs 1 and 2 which the device can receive:
– PDO 1:

Object 1400h

– PDO 2:

Object 1401h

COB-ID for PDO 1400h,

1401h

01h

uint32

rw

COB ID used by the PDO.
– PDO 1:

Default: 0x200 + Node-ID

– PDO 2:

Default: 0x300 + Node-ID

Transmission type 1400h,

1401h

02h

uint8

rw

Transmission type
Default: 255 (0xFF) – Event-triggered asynchronous transmission
Value range: 0 ... 255 (0x00 ... 0xFF)

Inhibit time 1400h,

1401h

03h

uint16

rw

Inhibit time, not used for RPDO.
Fixed: 0 (0x0000)

Compatibility entry 1400h,

1401h

04h

reserved

Event timer 1400h,

1401h

05h

uint16

rw

Event counter in [ms]. Default: 0 (0x0000)