B.2.10 Project data – Power operation

Stroke limit

FHPP

510

uint32

rw

Description

Maximum permitted stroke with active force control. With active force control, the
actual position relative to the start position must not change by more than the
amount specified in this parameter. In this way you can ensure that, if force control
is activated by mistake (e. g. missing work item), the axis will not perform an un-
controlled movement. This parameter is taken into account in all control modes in
which the position controller is not active in the status “Operation enabled.”

Monitoring can be deactivated when bit RCB1.B5 is set.

Value range: 0...4,294,967,295 Inc

CANopen / CI

60F6h

01h

uint32

rw

Min. Torque (min. permitted force/torque)

FHPP

511

uint16

rw

Description

This value represents the lowest permitted torque (force) of the motor. The
value is specified in 1/1000 of the rated torque (6076h / PNU 509).

Value range: 0...1000 (0x03E8).

CI access

60F6h

05h

uint16

rw

Max. Torque (max. permitted force/torque)

FHPP

512

Var

uint16

rw

Description

This value represents the highest permitted torque (force) of the motor. The
value is specified in 1/1000 of the rated torque (6076h / PNU 509).
Value range: 0...1000 (0x03E8).

CANopen / CI

6072h

– / 00h

Var

uint16

rw