5. Commissioning

5-19

Festo P.BE-MTR-DCI-CO-EN en 1209a

5. Save the position set with [Save]. Only then will the set-

tings be retained even when the power supply is switched
off or if there is a power failure.

6. Enter the next position record.

Digitalization faults of the analogue-digital convertor can
accumulate in the case of relative position movements which
occur frequently one after the other and lead to deviations of
the position values. If necessary, insert an absolute position
set or reference travel into the positioning cycle, in order to
correct deviations.