4 diagnostic memory – Festo Электромотор MTR-DCI User Manual

Page 196

Advertising
background image

6. Diagnostics and error display

6-12

Festo P.BE-MTR-DCI-CO-EN en 1209a

6.4

Diagnostic memory

The diagnostic memory contains the last 16 diagnostic mess-
ages. It is backed up if possible in the event of power failure.
If the memory is full, the oldest element will be overwritten
(ring buffer).

Structure of the diagnostic memory

Parameters

1)

CO/CI 20C8

h

PNU 200

CO/CI 20C9

h

PNU 201

CO/CI 20CA

h

PNU 202

Format

uint8

uint16

uint32

Meaning

Diagnostic event

Fault number

Time

Subindex 1

Current diagnostic message

Subindex 2

Previous diagnostic message

...

...

Subindex 16

Oldest diagnostic message

1)

see section B.2.6

Tab. 6/8: Diagnostic memory: Structure

Configuration of the diagnostic memory with parameter CO/CI 20CCh (PNU 204)

SI

Description

Specifi-
cation:

Min.

Max.

1

= 1: Record incoming and outgoing

*)

faults

= 2: Record only incoming faults

1

1

2

2

= 1: Resolution time stamp 10 ms
= 2: Resolution time stamp 1 ms

1

1

2

3

Deleting the diagnostic memory.
– Writing with value = 1 deletes the diagnostic memory
– Read will always be answered with value = 0.

0

0

1

4

Number of valid entries in the diagnostic memory.

0

0

16

*) outgoing fault = time point when the fault was quitted.

Tab. 6/9: Diagnostic memory: Configuration