Special features dependent on operating mode – Festo Электромотор MTR-DCI User Manual

Page 276

Advertising
background image

B. Reference – Festo Handling and Positioning Profile (FHPP)

B-58

Festo P.BE-MTR-DCI-CO-EN en 1209a

TA

Activities of the user

Internal conditions

TA8

Referencing finished or stopped.

Only for stop:
Stop = 1

→0

CCON = xxx0.xx11
CPOS = 0xxx.xxxN

TA9

Jogging positive = 0

→1

Stop = 1
CCON = xxx0.xx11
CPOS = 0xx0.Pxx1

TA10

Either
– Jogging positive = 1

→ 0

– CCON = xxx0.xx11
– CPOS = 0xxx.0xx1
or
– Stop = 1

→0

– CCON = xxx0.xx11
– CPOS = 0xxx.xxxN

TA11

Jogging negative = 0

→1

Stop = 1
CCON = xxx0.xx11
CPOS = 0xxP.xxx1

TA12

Either
– Jogging negative = 1

→ 0

– CCON = xxx0.xx11
– CPOS = 0xxN.xxx1
or
– Stop = 1

→0

– CCON = xxx0.xx11
– CPOS = 0xxx.xxxN

Key: P = positive edge, N = negative edge, x = any

Special features dependent on operating mode:

Operating
mode

Notes on specific features

Record Select

No restrictions.

Direct mode

TA2: The condition that no new record may be processed no longer applies.
TA5: A new record can be started at any time.

Advertising