Festo Электромотор MTR-DCI User Manual
Page 119

5. Commissioning
5-21
Festo P.BE-MTR-DCI-CO-EN en 1209a
In the positioning cycle [Demo posit tab] all position sets
in the position record table are executed one after the
other. If the position record table contains a position
record with speed v = 0, this position record and all the
following sets will not be executed; the positioning run
will be continued with position record 1.
4. Start the test run.
Note
With EMERG.STOP <Menu> you can interrupt the current
positioning procedure.
With DEMO STOP <Enter> you can interrupt the positioning
cycle [Demo posit tab]. The current position record will be
executed before the drive stops.
•
Check the positioning behaviour.
•
Check the positions displayed.
5. If necessary, optimize the settings for position records,
and for the basis points and the working range.