Diagnostic

Displays the system data and the currently effective settings (see chapter 4.3)

} Pos. set table

Displays the position record table

} Axis parameters

Displays axis parameters and data

} System

paramet.

Displays system parameters and system data

} CAN Bus Diag

Displays data for CANopen diagnosis

} Software

information

Displays the operating system version (firmware)

}

Positioning

1) 2)

Reference run and positioning runs for testing the position records (see chapter 4.4)

} Move posit. set

Start positioning run “Position set”

} Demo posit. tab

Start positioning run “Position set table”

} Homing

Start the reference run

}

Settings

1) 2)

Selection of the drive, parametrizing, programming the position sets ... (see chapter 4.5)

} Axis type

} Type DMES-...

Valve actuator DMES-...

} Type DNCE-...

Electric cylinder DNCE-...

} Rotation drive

Rotation axis with stop

} User config

Any linear drive

} Axis parameters

} Zero point

3)

Offset axis zero point

} Abs.min.pos

3)

Stroke limitation: Software end position, negative

} Abs.max.pos

3)

Stroke limitation: Software end position, positive

} SAVE...

Save parameters in EEPROM

} Homing
parameter

} Homing method

Select referencing (homing) method (stop, software limit switch...)

} Velocity v_sw

Positioning speed for searching for the reference point

} Velocity v_s0

Positioning speed for moving to the axis zero point

} SAVE...

Save parameters in EEPROM

} Position set

} Position nr.

Number of the position record (0...14)

} Pos set mode

Absolute or relative positioning

} Position

3)

Target position of the position set

} Velocity

Positioning speed of the position set

} SAVE...

Save parameters in EEPROM

} Password edit

Set up a local password with 3 figures for the control panel (see chapter 4.5)

} CAN parameter

Setting the field bus parameter

}

HMI control

1)

Presetting the device control via the control panel (see chapter 4.6)

}

LCD adjustment

Rotate the display in steps of 90°

1)

If necessary password protection

3)

Teach mode

2)

Controller interface must be deactivated, see [HMI] control] :HMI = on

Tab. 4/2: Menu commands (overview)