5. Commissioning

5-34

Festo P.BE-MTR-DCI-CO-EN en 1209a

5.4.4

PDO mapping

The mapping is pre-set (“static mapping”) and cannot be
altered by the configuration software of the master.

Note
If the data on the master side are not in the same form, but
saved, i. e. as byte array:

note that the representation of words and double words
appears in the “little endian” representation when trans-
mitted via CAN (lower-value byte first).

PDO mapping in FHPP

In FHPP mode the first PDO (8 bytes I/O data) for Transmit
and Receive is intended for the Record Select and Direct
modes; the second PDO (8 bytes I/O data) is used for FPC
(Festo Parameter Channel) parameterization.

Receive PDO 1 (FHPP standard)

Operating
mode

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Record Select

CCON

CPOS

Record
no.

reserved

reserved

Direct mode

CDIR

Nominal
value 1

Nominal value 2

Receive PDO 2 (FHPP-FPC)

Function

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Control

reserved

Parametrize

reserved

Subindex

Task identifier +
parameter number

Parameter value