B-50

Festo P.BE-MTR-DCI-CO-EN en 1209a

Drive Data

FHPP

1026

1...8

Array

uint32

rw

Description

General Drive Data

Output stage temp. 1026

1 (CI: 01h)

uint32

rw

Temperature of the end stage in °C. Value range: 0 ... 85

Output stage

Max. temp.

1026

2 (CI:02h)

uint32

rw

Maximum temperature of the end stage in °C. fixed: 80 (0x0050)

Rated motor

current

1026

3 (CI: 03h)

uint32

rw

Nominal motor current in [mA]
Value is automatically entered when an axis type is selected (PNU 1005/4).

Current limit 1026

4 (CI: 04h)

uint32

rw

Max. motor current in permil of rated current. Identical to PNU 1034.
Value range: 1...2000

Lower current limit 1026

5 (CI: 05h)

uint32

rw

= PNU1026.4 * (-1)

Device control 1026

6 (CI: 06h)

uint32

rw

Setting the device control (see PNU 125 / object 207Dh).
0: Control via HMI (control panel) or FCT, no control via fieldbus
1: Control via fieldbus – control interface (default)

Controller serial

number

1026

7 (CI: 07h)

uint32

rw

Serial number of the controller in format 0xDDMYYSSS:
DD (Day):

8 bits:

0x01...0x1F

M (month):

4 bits:

0x1...0xC

YY (Year):

8 bits:

0x00...0x63

SSS (serial number):

12 bits:

0x001...0xFFF

Following error

(permissible con-

touring error)

1026

8 (CI: 08h)

uint32

rw

Following error monitoring

Advertising