6. Diagnostics and error display

6-7

Festo P.BE-MTR-DCI-CO-EN en 1209a

6.3

Fault messages

6.3.1

Overview

Cate-
gory

Name, display

Description

Device
error

1)

Fault
number

Fault
LED

Status
bytes

2)

Fault

POSITION ERROR

Drag error

0x0001

31

ON

FAULT, DEV

Fault

MOTOR STOP

Motor stop

0x0002

106

ON

FAULT

Fault

HOMING-ERROR

Reference travel
fault

0x0004

32

ON

FAULT

Fault

OVERHEATING

Overtemperature
(ActTemp > 80°C)

0x0008

101

ON

FAULT

Fault

LOAD-POWER-
DOWN

Load voltage moni-
toring

0x0010

70

ON

FAULT

Fault

I2t-ERROR

Current monitoring
(i

2

t)

0x0020

100

ON

FAULT

Fault

HARDWARE-ERROR

Device fault

0x0040

52

ON

FAULT

Fault

TARGET POSITION
OUT OF LIMIT

Target position
cannot be reached

0x0080

2

ON

FAULT

War-
ning

ILLEGAL RECORD

Invalid record
number

0x0100

3

FLASHES WARN

Fault

PLEASE ENFORCE
HOMING RUN

Reference travel
required

0x0200

1

ON

FAULT

War-
ning

STANDSTILL
WARNING

Standstill
monitoring

0x4000

36

FLASHES WARN,

STILL

Fault

CAN-BUS INIT NO
PARAMETER ERROR

CAN bus fault:
Bus parameter not
set.

0x8000

51

ON

FAULT

Fault

CAN-BUS NO EXT.
SUPPLY VOLTAGE

CAN bus fault:
External CAN supply
fault.

0x8000

51

ON

FAULT

1)

see PNU 205/CO 2FF1/00

2)

FHPP status bytes, see section 5.5.2