Festo Электромотор MTR-DCI User Manual

Page 57

Advertising
background image

3. Installation

3-5

Festo P.BE-MTR-DCI-CO-EN en 1209a

The plug connectors on the Festo cables listed in the follow-
ing are designed to conform to protection class IP54 when
connectors are plugged in and secured, or when the connec-
tions on the MTR-DCI are equipped with protective caps.

Caution
Long lines reduce immunity to interference (EMC).

Observe the specified maximum cable lengths.

Connection

Cable

Designation

Length [m]

Serial interface

Programming cable

KDI-MC-M8-SUB-9-2,5

2.5 (max. 2.5)

Reference switch

Connecting cable

KM8-M8-GSGD-...

0.5 / 1 / 2 / 5

Voltage supply

Power supply cable

KPWR-MC-1-SUB-9HC-...

2.5 / 5 / 10
(max. 10)

Power supply

Supply cable

KPWR-MC-1-SUB-9HC-...

2.5 / 5 / 10
(max. 10)

Tab. 3/2: Overview of cables (accessories)

Complying with the IP protection class

Seal unused M8 connections with ISK-M8 protective caps
(accessories),

Tighten the union nuts/locking screws on the plugs by
hand.

Observe the permissible torques specified in the documenta-
tion for the cables and connectors used.