Festo Электромотор MTR-DCI User Manual
Page 57
3. Installation
3-5
Festo P.BE-MTR-DCI-CO-EN en 1209a
The plug connectors on the Festo cables listed in the follow-
ing are designed to conform to protection class IP54 when
connectors are plugged in and secured, or when the connec-
tions on the MTR-DCI are equipped with protective caps.
Caution
Long lines reduce immunity to interference (EMC).
•
Observe the specified maximum cable lengths.
Connection
Cable
Designation
Length [m]
Serial interface
Programming cable
KDI-MC-M8-SUB-9-2,5
2.5 (max. 2.5)
Reference switch
Connecting cable
KM8-M8-GSGD-...
0.5 / 1 / 2 / 5
Voltage supply
Power supply cable
KPWR-MC-1-SUB-9HC-...
2.5 / 5 / 10
(max. 10)
Power supply
Supply cable
KPWR-MC-1-SUB-9HC-...
2.5 / 5 / 10
(max. 10)
Tab. 3/2: Overview of cables (accessories)
Complying with the IP protection class
•
Seal unused M8 connections with ISK-M8 protective caps
(accessories),
•
Tighten the union nuts/locking screws on the plugs by
hand.
Observe the permissible torques specified in the documenta-
tion for the cables and connectors used.