Factory setting

32

42

52

62

Speeds v_sw, v_s0

%

1)

inc/s

~41 %
27000

~22 %
22400

~17 %
16800

~15 %
16800

Rated speed of the motor

rot/s
inc/s

55
66000

50
100000

50
100000

56.7
113400

Reference travel (homing) method

Reference switch, negative (near motor)

1)

% of the rated motor speed; max. = 50 %

Tab. 5/4: Factory setting of the reference travel parameters

[Hom. paramet.]

Param.

Description

[Homing method]

1)

sw.neg
(switch negative)

Homing to reference switch, negative

sw.pos
(switch positive)

Homing to reference switch, positive

bl.neg
(block negative)

Homing to fixed stop, negative

bl.pos
(block positive)

Homing to fixed stop, negative

[Velocity v_sw]

v_sw

Speed for searching for the reference point

[Velocity v_s0]

v_s0

Speed for moving to the axis zero point

[SAVE...]

Save parameters in EEPROM

1)

Further information on the reference travel (homing) method in chapter 1.6.3

.