6. Diagnostics and error display

6-13

Festo P.BE-MTR-DCI-CO-EN en 1209a

The faults are divided into logical groups according to the
fault numbers.

Group

Name

Comment

0

No fault active

1 ... 19

Processing fault

Examples: No reference travel, nominal position outside soft-
ware end positions, nominal value calculation not possible.
Although the system is OK, a user comand cannot be proces-
sed. In most cases there is a fault in operation.
Source: Sequence control, controller

20..29

Parameter fault

Example: Software end positions outside the working stroke.
A parameter lies within the limit values so that it can be writ-
ten by the user. During the new calculation of the controller,
it was ascertained that it is not permitted in the context of
the other parameters.
Note: Non-permitted parameters are rejected by the parame-
ter protocol and do not generate a fault in the controller.

30..49

Controller

Examples: Positioning timeout, reference travel not succes-
ful, drag error too large,
The task could not be processed correctly. No hardware fault
is recognized here. Source: Controller

50..69

Initialization

Fault in initializing the controller

70..79

Run time of controller

Fault in controller run time: Undervoltage, checksum

80 ... 89

reserved

90 ... 99

reserved

100 ... 109

Run time of motor

Run time of motor: Undervoltage, overtemperature,

110 ... 119

reserved

Tab. 6/10: Overview of fault numbers

A detailed description of the warnings and faults can be
found in section 6.3.2.