5. Commissioning

5-35

Festo P.BE-MTR-DCI-CO-EN en 1209a

Receive PDO 1 (FHPP standard)

Operating
mode

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Record Select

SCON

SPOS

Record
no.

RSB

Actual position

Direct mode

SDIR

Actual
value 1

Receive PDO 2 (FHPP-FPC)

Function

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Control

reserved

Parametrize

reserved

Subindex

Task identifier +
parameter number

Parameter value

PDO mapping with CiA 402

Receive PDO 1 (CiA 402)

1)

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Control word 6040h

Set
number
2032h

Operating
mode
6060h

Nominal value
– Positioning mode Setpoint (nominal) position

607Ah

– Power operation Nominal torque 6071h

1)

Evaluation sequence:
– Read the operating mode 6061h
– Accept the set number 2032h
– Accept nominal value (only if set number 0 is for “Direct set”. Otherwise the value from the set

list applies to the specified set).

– Execute control word 6040h.