7 notes on operation – Festo Электромотор MTR-DCI User Manual

Page 181

Advertising
background image

5. Commissioning

5-83

Festo P.BE-MTR-DCI-CO-EN en 1209a

5.7

Notes on operation

Take the following instructions and recommendations into
account when programming positioning systems with electric
axes:

Start-up behaviour and referencing

Warning
Incorrect parameterization can cause injury to people and
damage to property.

In the following cases reference travel is absolutely es-
sential in order that the basis coordinates and the work-
ing range can be set correctly:

Every time the logic voltage supply is switched on,

– when the measuring reference system (reference

travel method, axis zero point, direction of rotation)
has been modified (compare object 607E

h

),

– after failed/aborted reference travel.

Make sure that before starting reference travel the
axis stands in the direction of movement

in front of

the reference switch or stop.

Note
When the coupling or clamping element in the coupling
housing is loosened, the motor can be turned on its
longitudinal axis. The reference position will then be lost.

Carry out a new reference run.

Note

When the power supply is switched off, wait for approx.
5 seconds before switching the device on again.