Overview of parameters involved (see section B.2.9)

Parameters

Description

FCT

PNU

CI

Power operation

1)

Stroke limitation

x

510

60F6/01h

Minimum torque

x

511

60F6/05h

Maximum torque

x

512

6072h

Force target window (tolerance)

x

552

60F6/03h

Damping (rest) time in [ms]

x

553

60F6/04h

Max. permitted speed

x

554

60F6/02h

Start

CPOS.B1 = positive edge
(CDIR.B0 = nominal position absolute/relative)

Reply message

SPOS.B2 = 0: Motion Complete
SPOS.B1 = positive edge: Quit Start
SPOS.B4 = 1: Drive moves

Requirement

Device control by PLC/field bus
Controller must be in status “Operation enabled”

1) Further parameters:
6071h Target torque

6076h Rated torque

6077h Actual torque

6087h Torque slope

6088h Torque profile type

CDIR.B5 Stroke limitation active/inactive

Tab. 5/22: Parameters involved in Direct mode (power operation)