5. Commissioning

5-36

Festo P.BE-MTR-DCI-CO-EN en 1209a

Receive PDO 2 (CiA 402)

1)

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Velocity 6081h

Acceleration 6083h

1)

The velocity and acceleration are only accepted if the set number received via PDO 1 is 0 for “Direct
set”. It is not possible to overwrite the set list by PDO.

Transmit PDO 1 (CiA 402)

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Status word 6041h

Set
number
2032h

Operating
mode
6061h

Actual value
– Actual position 6064h

1)

– Actual torque 6077h

1)

With the Transmit PDO a new transmission is only sent if the value has changed by more than 1.
(To avoid high bus loading caused by jitter on the position decoder).

Transmit PDO 2 (CiA 402)

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

Reserved (this PDO is not supported).