6. Diagnostics and error display

6-11

Festo P.BE-MTR-DCI-CO-EN en 1209a

Fault

Remedy

Possible cause

PLEASE ENFORCE
HOMING RUN!

When starting a positioning record:
– A valid reference travel has not

yet been conducted.

– Due to a logic voltage failure the

reference position has been lost.

Carry out homing.

POSITION ERROR

Position error (following error).
– The drive is blocked.
– The parameterised speed cannot

be reached.

– The effective load is too heavy.

Check:
– the mechanics of the drive,
– the speed of the positioning re-

cord.

TARGET POSITION
OUT OF LIMIT

Target position fault
– The specified target position is

outside the permitted positioning
range.

– the software end positions,
– the target position,
– the reference of the nominal

position (absolute or relative).

Tab. 6/7: Fault messages