Festo Электромотор MTR-DCI User Manual

Page 163

Advertising
background image

5. Commissioning

5-65

Festo P.BE-MTR-DCI-CO-EN en 1209a

1

Low speed phase 1
(slow travel)

2

Maximum speed for
phase 2

3

Acceleration/
deceleration

4

Duration phase 1

CPOS.B3 or
CPOS.B4
(Jogging
positive/
negative)

Speed v(t)

t [s]

1

0

1

2

3

4

3

Fig. 5/2:

Sequence diagram for jogging mode

Overview of parameters involved (see section B.2.9)

Parameters involved

Description

FCT

PNU

CO/CI

Speed phase 2 in (inc/s)

x

531

20ED/21

Acceleration or deceleration (inc/s

2

)

x

532

20EE/21

Duration phase 1 in ms

x

534

20E9/21

Start (FHPP)

CPOS.B3 = positive edge: Jog positive (forwards)
CPOS.B4 = positive edge: Jog negative (backwards)

Reply message (FHPP)

SPOS.B4 = 1: Drive moves
SPOS.B2 = 0: (Motion Complete)

Requirement

Device control by PLC/field bus
Controller must be in status “Operation enabled”

Tab. 5/17: Parameters involved in jogging mode