5. Commissioning

5-24

Festo P.BE-MTR-DCI-CO-EN en 1209a

Data profile (CAN profile)

Possible data profiles:

FHPP:
Control of the MTR-DCI is made as per Festo Handling
and Positioning Profile.

CiA 402:
The MTR-DCI is activated and parameterised in ac-
cordance with CiA 402.

An

invalid data profile is preset (displayed as “???”).

This ensures that the correct data profile has to be en-
tered during commissioning or when replacing the unit.

For information on the data profile see section 1.2.2.

Set the data profile as follows:

1. Select [Settings] [CAN parameter] [CAN profile]

(see also section 4.5).

2. Press <Enter> to display the current data profile.

3. Use the arrow keys to set the desired data profile.

4. Accept the data profile with OK <Enter>.

The pre-set profile takes effect immediately, and is saved
against network failure.

} Settings

CAN parameter

CAN profile

CAN profile

FHPP

ESC<Menu>

EDIT <-->

OK <Enter>