Festo Электромотор MTR-DCI User Manual

Page 318

Advertising
background image

C. Reference – CANopen and CI objects

C-42

Festo P.BE-MTR-DCI-CO-EN en 1209a

Drive Data

CANopen / CI

6510h

01h...08h,
22h, 31h, 32h,
40h...43h
45h, A0h, A1h

Record

int16, uint16, uint32

ro/rw

Description

General motor data, see PNU 1026, section B.2.17.

Output Stage

Temp.

6510h

31h (FHPP: 1)

int16 (FHPP: uint32)

ro

Temperature of the end stage in °C.
Value range: -40 ... 85 (SI 01h: 0 ... 85)

Output Stage

Max. temp.

6510h

32h (FHPP: 2)

uint16 (FHPP: uint32)

ro

Maximum temperature of the end stage in °C.

Motor Rated

Current

6510h

40h (FHPP: 3)

uint32 (FHPP: uint32)

ro

Rated motor current in mA
Value is automatically entered when an axis type is selected (PNU 1005/4).

Current Limit 6510h

41h (FHPP: 4)

uint16 (FHPP: uint32)

ro

Maximum motor current, identical to PNU 1034.

Lower Current Limit 6510h

42h (FHPP: 5)

in16 (FHPP: uint32)

ro

Lower current limit value in 1/1000 of the rated motor current

I/O Control 6510h

43h (FHPP: 6)

uint16 (FHPP: uint32)

rw2

Control of the control interface (see also object 207Dh).

Controller Serial

Number

6510h

A0h (FHPP: 7)

uint32 (FHPP: uint32)

ro

Serial number of the controller in format 0xTTMYYSSS:

Following Error 6510h

22h (FHPP: 8)

uint32 (FHPP: uint32)

ro

Drag fault monitoring

Current actual value 6510h

45h

1)

int16

ro

Current actual value

Firmware number

6510

A1h

2)

uint32

ro

FHPP

1026

1...8

Array

uint32

ro/rw

1)

Object not available via FHPP

2)

FHPP PNU 101

Advertising