Festo Электромотор MTR-DCI User Manual
Page 26
![background image](/manuals/464466/26/background.png)
1. System overview
1-4
Festo P.BE-MTR-DCI-CO-EN en 1209a
You can parametrize and commission the MTR-DCI as follows:
–
with the FCT software package via the RS232 interface of
your PC
–
with the optional control panel with display and 4 operat-
ing buttons (only MTR-DCI-...-H2)
–
via the field bus.
Functions
HMI
FCT
Field bus
Parametrizing
– Selecting the axis type and the axis para-
meters
– Specifying a gear factor (with external
gears)
– Uploading/downloading configuration
data
– Saving different configurations in projects
x
–
–
–
x
x
x
x
x
x
x
–
Position records
– Compiling a position set table with set
number, target position, positioning
mode, positioning speed, acceleration
x
x
x
Commissioning
– Reference run (homing)
– Jog mode
– Teaching positions
– Moving in individual steps
– Starting and stopping positioning
procedures while commissioning
– Extended test functions e.g. status
displays
– Testing or demonstrating the position
records
x
x
x
–
x
(x)
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
Diagnostics/
Service
– Reading and displaying diagnostic data
x
x
x