3. Installation
3-17
Festo P.BE-MTR-DCI-CO-EN en 1209a
Power supply to the bus interface
32
42
1)
52
1)
62
1)
Internal supply:
– Do not connect pins 6 and 9
– CAN bus (pins 2, 3, 7) potential refers to (load) voltage supply of
the MTR-DCI.
—
x
2)
x
2)
x
2)
External power supply:
– Pins 6 and 9 must be supplied with 24 V (logic voltage)
– CAN bus (pins 2, 3, 7) potential refers to the bus voltage supply
(enables electrically isolated bus connection).
x
2)
x
x
x
1)
Depends on parametrizing
– “CAN voltage supply (CAN power supply)” (see section 5.2.7) or
– [CAN volt.supply] on the control panel (see section 4.5, [CAN parameter])
2)
default
Tab. 3/9: Power supply for bus interface
Caution
Damage to other field bus devices
If you are using the external logic power supply via the
field bus adapter FBA-... (see chapter Accessories) there
will be a voltage of DC 24 V at pin 9.
•
Check whether there is any danger for other field bus
slaves.
•
Note the pin assignment in accordance with the assem-
bly instructions for the field bus adapter.