3. Installation

3-17

Festo P.BE-MTR-DCI-CO-EN en 1209a

Power supply to the bus interface

32

42

1)

52

1)

62

1)

Internal supply:
– Do not connect pins 6 and 9
– CAN bus (pins 2, 3, 7) potential refers to (load) voltage supply of

the MTR-DCI.

x

2)

x

2)

x

2)

External power supply:
– Pins 6 and 9 must be supplied with 24 V (logic voltage)
– CAN bus (pins 2, 3, 7) potential refers to the bus voltage supply

(enables electrically isolated bus connection).

x

2)

x

x

x

1)

Depends on parametrizing

– “CAN voltage supply (CAN power supply)” (see section 5.2.7) or
– [CAN volt.supply] on the control panel (see section 4.5, [CAN parameter])

2)

default

Tab. 3/9: Power supply for bus interface

Caution
Damage to other field bus devices

If you are using the external logic power supply via the
field bus adapter FBA-... (see chapter Accessories) there
will be a voltage of DC 24 V at pin 9.

Check whether there is any danger for other field bus
slaves.

Note the pin assignment in accordance with the assem-
bly instructions for the field bus adapter.