3. Installation

3-11

Festo P.BE-MTR-DCI-CO-EN en 1209a

3.4

Serial interface

Serial interface for parametrizing, commissioning and diag-
nosing

In order to connect a PC to the MTR-DCI, use exclusively the
following cable:
– Programming cable KDI-MC-M8-SUB-9-2,5

If necessary, remove the protective cap from the serial
interface of the MTR-DCI.

Connect the following terminals with the programming
cable:

the connection socket on the MTR-DCI

a serial interface COMx of the diagnostic PC.

M8x1 socket

Description

1

2

4

3

1

GND

Ground

2

TXD

RS232 transmitting cable

1)

3

RXD

RS232 receiving cable

1)

4

---

reserved for servicing personnel –
do not connect.

1)

The levels correspond to the RS232 standard
Data transfer rate: 9600 bit/s

Tab. 3/6: Pin assignment of the serial interface on the

MTR-DCI