B. Reference – Festo Handling and Positioning Profile (FHPP)

B-46

Festo P.BE-MTR-DCI-CO-EN en 1209a

Homing Velocities

FHPP

1012

1, 2

Array

uint32

rw

Description

Speeds during homing in [inc/s].

Search REF 1012

1

uint32

rw

Speed when searching for the reference point REF in [inc/s]
Value range:
MTR-DCI-32:

200...33000

MTR-DCI-42:

200...50000

MTR-DCI-52:

200...50000

MTR-DCI-62:

200...56700

Default:
MTR-DCI-32:

27000

MTR-DCI-42:

22400

MTR-DCI-52/62: 16800

Search AZ 1012

2

uint32

rw

Speed of travel to the axis zero point AZ in [inc/s]
Value range:
MTR-DCI-32:

200...33000

MTR-DCI-42:

200...50000

MTR-DCI-52:

200...50000

MTR-DCI-62:

200...56700

Default:
MTR-DCI-32:

27000

MTR-DCI-42:

22400

MTR-DCI-52/62: 16800

CANopen / CI

6099h

01h, 02h

Array

uint32

rw

CiA 402: Homing Speeds

Homing Required (reference travel necessary)

FHPP

1014

Var

uint8

rw

Description

Defines whether or not reference travel must be carried out after switching on
in order to carry out positioning tasks.
When the logic voltage supply of the MTR-DCI-CO has been switched on,
a reference run must always be carried out.
Fixed = 1: Reference travel must be carried out

CANopen / CI

23F6h

– / 00h

Var

uint8

rw

Homing Max. Torque (reference travel max. torque)

FHPP

1015

Var

uint8

rw

Description

Maxmum current consumption during reference travel in percent of the rated
current (see PNU 1035 / CI object 6075h).
Compare PNU 1034 (specification in permil).
Value range: 0 ... 200 (0xC8). Default: 150 (0x96)